Testing assuming factories and warehouses
Testing assuming factories and warehouses
Test method
Apply COOL TIGHT series (grey colour) on part of a corrugated metal roof and apply conventional coating (grey colour) on the other half part of it. Then, measure the surface temperature and indoor temperature at the centre of the warehouse. Also, measure the daytime
temperature distribution by thermographic measurement.

Test result
Comparison of applications between COOL TIGHT series and conventional coating; average difference of 11.6°C at the roof surface and average difference of 4.6°C for the indoor temperature are confirmed.

Temperature distribution of the roof surface by thermographic measurement

Testing assuming factory yard
Test method
Measure the temperature change of the metal roof surface in the daytime of the unpainted roof and the repainted roof (COOL TIGHT
series). As a result, a temperature reduction effect of 12.1°C was confirmed as an average temperature difference from 12:00 to 14:00. Colour: Grey